    • High Pressure Laboratory Reactor Stainless Steel Tanks Vessel

        THR Series High Pressure Reactor adopt module heating method, which is quick heating and precise temperature control.THR series all are internal magnetic stirring, when magnetism arrive 250℃, degaussing phenomenon will happen, so if operating in over 250℃ condition, please choose TOPTION MHR Series High Pressure Reactor.

  • High Pressure Laboratory Reactor Stainless Steel Tanks Vessel;
  • High Pressure Laboratory Reactor Stainless Steel Tanks Vessel;

                • Technology Parameters Of High Pressure Laboratory Reactor Stainless Steel Tanks Vessel


                  The stirring reactor laboratory miniature high-pressure reaction kettle

                  Model

                  THR50

                  THR100

                  THR250

                  THR500

                  Material capacity(L)

                  50ml

                  100ml

                  250ml

                  500ml

                  The working interface

                  LCD Display

                  LCD Display

                  LCD Display

                  LCD Display

                  The maximum operating temperature

                  250℃

                  250℃

                  250℃

                  250℃

                  The maximum operating temperature with PTFE Liner

                  180℃

                  180℃

                  180℃

                  180℃

                  Heating  mode

                  Module heating

                  Module heating

                  Module heating

                  Module heating

                  The heating power

                  1.2KW

                  1.2KW

                  1.5KW

                  2.0KW

                  Stirring speed

                  0-1200rpm

                  0-1200rpm

                  0-1300rpm

                  0-1300rpm

                  Stirring method

                  The internal magnetic stirring

                  The internal magnetic stirring

                  The internal magnetic stirring

                  The internal magnetic stirring

                  The stirring power

                  40W

                  40W

                  40W

                  80W

                  The  maximum working pressure

                  10Mpa

                  10Mpa

                  10Mpa

                  10Mpa

                  Materials of construction

                  SS304 (standard); (SS316L Alloy TA2, ALLOY C-276, Nickel ALlloy, Zirconium materials are optional)

                  PTFE  liner

                  Optional

                  Note:
                    1. Max volume 2000ml could be customized.
                    2.Suitable for the material which temp 
                  <250℃ and is   nonmagnetic.
                    3.Temperature timing set, temp. set when working, this function is optional.

  • High Pressure Laboratory Reactor Stainless Steel Tanks Vessel;

                  • Product Application  Of High Pressure Laboratory Reactor Stainless Steel Tanks Vessel


                  Chemistry, Pharmaceutical, Macromolecule, Metallurgy, Environmental Protection,etc, chemical process areas. For instance: high pressure reaction, hydrogenation reaction, catalytic reaction, synthetic process, pharmaceuticalsynthesis, high pressure polymerization, nano synthesis,  infrared detection,etc.


                    Product Details Description Of High Pressure Reaction


                    1.Pressure Gage-monitor working pressure in reactor.

                    2.Explosion Valve-Protect reactor over pressure working.

                    3.Temperature Sensor Plug-monitor the temperature in reactor, connect with thermocouple.


                    4.Needle valve-air inflow,exhaust or sampling.

                    5.Handlebar-to teardown reactor lid.

                    6.Temperature measure jacket tube-used to insert temperature sensor.


                    7.Accused of bottom tube-used to sample during reaction.

                    8.Reactor lid lock screw-uniform distribution 6pcs in toital ,clockwise is tight,anticlockwise is loose.

                    9.Reactor body-coefficient of material charging is 80% of reactor whole volume,not suitable for all kinds of medium


  • High Pressure Laboratory Reactor Stainless Steel Tanks Vessel;
            • CE Certification Of High Pressure Reactor With Magnetic Stirrer

  • High Pressure Laboratory Reactor Stainless Steel Tanks Vessel;
    High Pressure Laboratory Reactor Stainless Steel Tanks Vessel;
  • High Pressure Laboratory Reactor Stainless Steel Tanks Vessel;
    High Pressure Laboratory Reactor Stainless Steel Tanks Vessel;