• What’s Price Of Calibration Water Bath?

    TOPTION calibration water bath is applicable to the measurement, biochemistry, petroleum, meteorology, energy, environmental protection, medicine and other departments and the production of thermometers, temperature controllers, temperature sensors and other manufacturers for physical parameters testing.



  • Technical parameters of TOPTION this set calibration water bath


    Model

    Temp. range(℃)

    Temp.  fluctuation(℃)

    Temp.  uniformity

    (℃)

    Working area   dimension (mm)

    Capacity(L)

    Total power(KW)

    YH-40A

    -40~100

    ±0.005-0.01/30min

    ±0.005-0.01

    Ф150×480

    23

    3.0


  • Main features of laboratory calibration water bath

    1. Calibration water bath is a kind of high precision automatic control temperature verification device.

    2. With good temperature stability, temperature field uniformity, high temperature control precision, easy to operate, high efficiency.

    3. The refrigeration system adopts the imported air-cooled fully closed compressor unit, with multiple protection of over current and over temperature.

    4. Intelligent microcomputer software control, optional rs-232 or 485 communication interface, and could achieve computer connection control.

    5. The control instrument adopts large screen LCD display, beautiful and generous.

    6. PID software can be automatically set or manual adjustment.

    7. Computer software can fix the temperature deviation, make the precision of the digital display ±0.001 ℃.

  • Precautions for use of calibration water bath


    1. Liquid medium should be added into the tank before use. (the liquid level of the medium must be checked before starting the machine daily).


    2. The instrument has two drain valves on the left side, a drain valve on the bottom and an overflow valve on the top. (Note: open the relief valve at work and close the relief valve at rest)


    3. With the power of 50Hz 220V, the power should be greater than or equal to the total power of the instrument, and the power must have a good “grounding” device.


    4. Device should be placed in ventilated dry place, leave obstacles 300 ㎜ distance back and sides.


    5. After use, all the switches are off, unplug the power plug.

  • TOPTION as ISO & CE certification lab solution provider
    , main products including: molecular distillation equipment,rotary evaporator, glass reactor, heating and cooling circulators, etc. Please contact [email protected]
    for detail. 